Calculateur de l’indice d’oxygénation
Calculer l’indice d’oxygénation conventionnel brut à partir de mesures contemporaines pendant une ventilation mécanique invasive.
Partager l’outil sans les valeurs saisies.
La révision clinique doit être complétée.
Cet outil fait partie de la bibliothèque PharmaTek. Son calcul reste indisponible au public jusqu’à la validation de sa formule, de ses limites et de ses sources.
Explorer les outils accessiblesSources, population et validation
- État
- clinical-review-pending
- Version de la méthode
- Conventional oxygenation-index arithmetic v1: OI = (FiO2 [fraction] × ventilator-reported mean airway pressure [cmH2O] × 100) / arterial PaO2 [mmHg]. FiO2 accepts an explicitly tagged fraction or percent and is normalized to a fraction. The output is a raw, unrounded numeric index with no severity band or threshold
- Population
- Invasively mechanically ventilated patients for whom source-population applicability has been independently established. The equation is established in neonatal and pediatric critical care and has been studied observationally in intubated adults. Delivered FiO2, ventilator-reported mean airway pressure, and arterial PaO2 must be contemporaneous steady-state measurements from one documented ventilation time point, with arterial-sample identity, units, measurement quality, and timing verified.
- Limites et exclusions
- Noninvasive respiratory support; no ventilator-reported mean airway pressure; transient desaturation or changing-support measurements; non-contemporaneous values; or unverified ventilation mode, delivered FiO2, ventilator accuracy, arterial-sample identity, units, measurement quality, or documentation timing. · SpO2, capillary PO2, or venous PO2 substituted for arterial PaO2; oxygen saturation index or another saturation-based equation; inferred FiO2 or mean airway pressure; or population-specific interpretation not independently established. · Any severity band, cutoff, threshold, ECMO or intubation decision, diagnosis, prognostic or mortality claim, monitoring schedule, treatment, management, or other clinical decision.
Origine de l’outil PharmaTek
Outil importé de la bibliothèque PharmaTek de MDose. Aucune date de révision clinique indépendante n’est documentée dans cette version.
- Bibliothèque source
- PharmaTek · MDose
- Version importée
- 4b66536936ed
- État de publication
- Révision clinique en cours