Calculateur de l’index cardiaque et des résistances vasculaires systémiques
Calculer l’index cardiaque, le gradient PAM–PVC, la RVS et l’IRVS numériques à partir du débit cardiaque, de la surface corporelle, de la PAM et de la PVC explicitement fournis pour le même intervalle hémodynamique.
Partager l’outil sans les valeurs saisies.
La révision clinique doit être complétée.
Cet outil fait partie de la bibliothèque PharmaTek. Son calcul reste indisponible au public jusqu’à la validation de sa formule, de ses limites et de ses sources.
Explorer les outils accessiblesSources, population et validation
- État
- clinical-review-pending
- Version de la méthode
- Numeric hemodynamic arithmetic v1 using explicitly supplied values: cardiac index (CI, L/min/m²) = measured or independently established cardiac output (CO, L/min) / explicitly supplied body surface area (BSA, m²); pressure gradient = independently established mean arterial pressure (MAP, mmHg) - central venous pressure (CVP, mmHg); systemic vascular resistance (SVR, dyn·s/cm^5) = 80 × (MAP - CVP) / CO; systemic vascular resistance index (SVRI, dyn·s·m²/cm^5) = 80 × (MAP - CVP) / CI; the conventional unit-conversion factor is exactly 80 and this arithmetic requires MAP >= CVP
- Population
- People with measured or independently established cardiac output, explicitly supplied BSA, independently established MAP, and measured or independently established CVP from the same hemodynamic interval and a compatible measurement context, with pressure transducers leveled and zeroed and waveform quality checked as relevant, and measurements sufficiently steady for the arithmetic. MAP must be established independently rather than estimated by this calculator.
- Limites et exclusions
- Estimated or derived MAP from systolic and diastolic pressure, calculated or derived BSA, derived cardiac output, substitution of a missing value, or validation of any supplied measurement. · Measurements from different hemodynamic intervals, incompatible measurement methods or contexts, pressure measurements without appropriate leveling, zeroing, or waveform-quality review when relevant, insufficiently steady measurements, or MAP below CVP. · Normal ranges, cutoffs, thresholds, high/low or hemodynamic-state labels, diagnosis, prognosis, resuscitation, fluid, vasopressor, inotrope, treatment, management, or any other clinical decision.
Origine de l’outil PharmaTek
Outil importé de la bibliothèque PharmaTek de MDose. Aucune date de révision clinique indépendante n’est documentée dans cette version.
- Bibliothèque source
- PharmaTek · MDose
- Version importée
- 4b66536936ed
- État de publication
- Révision clinique en cours