Calculateur de la surface valvulaire aortique

Calculer la surface effective brute de la valve aortique à partir d’une seule étude échocardiographique vérifiée d’une valve native chez l’adulte avec l’équation de continuité Doppler.

Révision clinique en cours

La révision clinique doit être complétée.

Cet outil fait partie de la bibliothèque PharmaTek. Son calcul reste indisponible au public jusqu’à la validation de sa formule, de ses limites et de ses sources.

Explorer les outils accessibles
Sources, population et validation
État
clinical-review-pending
Version de la méthode
Adult native-aortic-valve Doppler continuity-equation arithmetic v1: LVOT cross-sectional area is either derived as π × (LVOT diameter [cm] / 2)^2 or supplied as an explicitly measured direct echocardiographic LVOT area [cm²]; effective aortic valve area [cm²] = LVOT area [cm²] × LVOT pulsed-wave systolic VTI [cm] / aortic-valve continuous-wave systolic VTI [cm]. Diameter accepts cm or mm, direct area accepts cm² or mm², and outputs are raw and unrounded
Population
Adults undergoing a resting assessment of a native aortic valve for whom the Doppler continuity equation is independently established as applicable. LVOT geometry, pulsed-wave LVOT VTI, and continuous-wave aortic-valve VTI must come from one technically adequate echocardiographic examination under a comparable hemodynamic state, with verified measurement identities, acquisition levels, Doppler alignment, beat averaging or matched-RR acquisition, units, and source values. Direct LVOT area must be an echocardiographic measurement corresponding to the adopted acquisition level.
Limites et exclusions
Pediatric, prosthetic-valve, stress or projected-area, hybrid CT/echo, anatomic valve planimetry, or intervention-planning use; measurements from different studies or hemodynamic states; inferred or mixed imaging identities; or an LVOT area from CT silently combined with echocardiographic VTI measurements. · Dynamic subaortic obstruction, a subaortic membrane, an unusable or skewed LVOT flow profile, inadequate LVOT geometry, incorrect pulsed-wave sample placement, inadequate continuous-wave alignment, unverified beat averaging or matched-RR acquisition, or any other technically inadequate or unverified acquisition context. · Any stenosis cutoff, grade, category, diagnosis, prognosis, intervention threshold, procedure decision, monitoring recommendation, management guidance, treatment advice, or interpretation without the complete echocardiographic and clinical assessment.
Origine de l’outil PharmaTek

Outil importé de la bibliothèque PharmaTek de MDose. Aucune date de révision clinique indépendante n’est documentée dans cette version.

Bibliothèque source
PharmaTek · MDose
Version importée
4b66536936ed
État de publication
Révision clinique en cours

POURSUIVRE AVEC MDOSE

Un outil. Un premier lien.

Recevez des nouvelles des outils ou discutez d’une collaboration. L’utilisation de PharmaTek reste accessible sans laisser vos coordonnées.

Médecins et partenaires

Indiquez seulement vos coordonnées. Les renseignements de santé et les dossiers de patients ne doivent pas être transmis ici.